TECHNIQUE AND PROCEDURES FOR PRIMER TESTING

Authors
  1. Chevrette, P.
Corporate Authors
Defence Research Establishment Valcartier, Valcartier QUE (CAN)
Abstract
This Note gives a description of an electric primer testing technique, the instrument calibration procedures and the operating instructions for such tests. The technique consists in remotely firing a primer in a closed vessel by means of an electronically controlled voltage source. Voltage and pressure signals, transmitted from the closed vessel by a strain type transducer, are displayed on an oscilloscope screen. Primer filament resistance is also measured prior to firing.
Report Number
TN-1984/71 —
Date of publication
15 Oct 1971
Number of Pages
21
DSTKIM No
71-08465
CANDIS No
11883
Format(s):
Hardcopy;Originator's fiche received by DSIS