DEPTH DOSES IN UNIT DENSITY PHANTOM USING THE FRICKLE DOSIMETER

Authors
  1. Wilson, R.
Corporate Authors
Defence Research Chemical Labs, Ottawa ONT (CAN)
Abstract
Depth dose curves in a masonite phantom were obtained using the ferrous-ferric sulphate dosimeter at X-ray energies from 50 kev effective to 160 kev effective and with Co60 gammas in unilaterial and rotational fields. A comparison was made with results obtained at these energies using ionisation chambers. G values for the Ferrous-ferric system were determined at the energies employed.
Report Number
DRCL-307 — Previously accessioned as DSIS 59/14630
Date of publication
15 Jun 1959
Number of Pages
15
DSTKIM No
92-03804
CANDIS No
127150
Format(s):
Hardcopy;Originator's fiche received by DSIS