DETERMINATION OF HYDROXYL EQUIVALENT WEIGHT OF POLYEPICHLOROHYDRIN, LINEAR AND BRANCHED GLYCIDYL AZIDE POLYMERS BY INFRARED ABSORPTION SPECTROSCOPY

PDF

Authors
  1. Lussier, L.S.
  2. Ahad, E.
  3. Ampleman, g.
Corporate Authors
Defence Research Establishment Valcartier, Valcartier QUE (CAN)
Abstract
The hydroxyl equivalent weight (HEW) of a prepolymer is of fundamental value for energetic formulation processing. This document describes the application of the infrared absorption spectroscopy to the determination of HEW of prepolymers used as binders in energetic formulations. According to this study, this technique can be applied to polyepichlorohydrin (PECH) type polymers. On the other hand, due to a peculiarity of glycidyl azide polymer (GAP), there is a need for a more statistically sampled size before this technique can be applied as a reliable and universal method to this type of polymers. For the time being, this technique can only be applied indirectly to GAP type binders.
Keywords
GAP (Glycidyl azide polymer) propellants
Report Number
DREV-4714/93 —
Date of publication
01 Dec 1993
Number of Pages
52
DSTKIM No
94-02936
CANDIS No
136176
Format(s):
Hardcopy;Originator's fiche received by DSIS;Document Image stored on Optical Disk