CAUSES OF POWER DEGRADATION IN A HIGH-REPETITION RATE TEA CO2 LASER

Authors
  1. Suart, R.D.
  2. Levesque, R.J.
  3. Snelling, D.R.
Corporate Authors
Defence Research Establishment Valcartier, Valcartier QUE (CAN)
Abstract
Measurements were made of the output power, gas charge composition and electrical discharge properties during typical runs of the Intermediate High Repetition Rate Laser (Intermediate HRRL). In the present configuration of the laser, the conversion of CO2 into CO and O2 appears to be the only important effect leading to power loss in the HRRL unless there are bright arcs present in the electrode assembly.
Report Number
709/74 —
Date of publication
15 Mar 1974
Number of Pages
50
DSTKIM No
75-00141
CANDIS No
24163
Format(s):
Hardcopy;Originator's fiche received by DSIS

Permanent link

Document 1 of 1