THE EVALUATION OF A 500 WATT THERMOELECTRIC POWER SOURCE, PP-6075 (XE-2)

Authors
  1. Sawchuk, R.A.
  2. Hayashi, R.
Corporate Authors
Defence Research Establishment Ottawa, Ottawa ONT (CAN)
Abstract
Two 500 watt thermoelectric power sources were evaluated by the Defence Research Establishment Ottawa from January 1977 to July 1977. A total of 393 operational hours were accumulated over a temperature range of -25C to +25C. Fuel consumption at maximum rated power was in the range of 1.6 to 1.8 kg/h which translates to an overall efficiency of 2.2 to 2.8%. Although for these units shortcomings were observed in the areas of reliability, maintainability and multifuel capability, the evaluation demonstrated the feasibility of using thermoelectric technology to power tactical military equipment.
Report Number
843 —
Date of publication
15 Feb 1981
Number of Pages
33
DSTKIM No
81-02978
CANDIS No
33854
Format(s):
Hardcopy;Originator's fiche received by DSIS