GUIDELINES FOR EVALUATION OF CF INDOOR FIRING RANGES

Authors
  1. O'Neill, J.L.
Corporate Authors
Defence and Civil Inst of Environmental Medicine, Downsview ONT (CAN)
Abstract
A guideline has been prepared to assist the Preventive Medicine Technician (PMT) at the base level to monitor inorganic lead concentrations in indoor firing ranges during weapons firing. From the mean lead levels obtained, safe occupancy periods may be derived from the maximum allowable exposure table included in the report. The complete technical approach which includes air monitoring and ventilation measurement techniques is outlined in detail. The sampling strategy, if followed should be of assistance to the PMT in evaluating an indoor firing range. Also included are housekeeping recommendations regarding safe practices.
Report Number
TC-82-C-52 — Technical Communication
Date of publication
15 Oct 1982
Number of Pages
15
DSTKIM No
83-00346
CANDIS No
38495
Format(s):
Hardcopy;Originator's fiche received by DSIS