Measurement of Radiation Protection Factors for Contaminated Vehicles
- Authors
- Corporate Authors
- Defence Research Establishment Ottawa, Ottawa ONT (CAN)
- Abstract
- The gamma-ray radiation protection factor for contaminated vehicles has been defined and measured for two locations inside the CF Grizzly. The measurements were performed with a 60Co gamma-ray source at the DREO fallout field simulation facility. In the driver's seat, the protection factor was observed to be 11.9, while in a passenger's position closer to the rear of the vehicle, the protection factor was considerably smaller, at 8.0.
- Keywords
- CF Grizzly;Gamma ray radiation;Radiation Protection Factor
- Report Number
- DREO-TM-1999-070 — Technical Memorandum
- Date of publication
- 01 Mar 1999
- Number of Pages
- 32
- DSTKIM No
- 99-01746
- CANDIS No
- 511740
- Format(s):
- Hardcopy;Document Image stored on Optical Disk
Document 1 of 1