Abstract
This report presents a summary of the measurements performed using the Compact ATmospheric Sounding Interferometer (CATSI) for the standoff detection of toxic chemical vapours at DSTL, Porton Down, UK in June 2005. This work is based on the passive standoff detection of chemical warfare agent (CWA) simulants such as SF6, NH3 and TEP; precursors such as DMMP; and toxic chemical vapours such as phosgene and GB. The measurements were performed for a variety of concentrations and at low thermal contrast in an open-air environment. Some chemicals were released in the presence of yellow smoke to act as an obscurant. The measurements collected during the trial were used to evaluate the performance and capability of the CATSI sensor for detecting, identifying and quantifying a chemical vapour cloud at distances between 500 m and 1.5 km. The results show that CATSI was able to detect and identify all of the chemical vapours released during the trial, including the CWA. The measurements made in the presence of yellow smoke provide some preliminary evidence that some obscurants do not significantly affect the detection capability of a passive standoff sensor. The measurements of GB in the field also demonstrate that the atmosphere has an insignificant effect on the signature of the pure agent. The work performed in this field trial is also useful for validating the approach and methodology used in the new engineering development model of the CATSI system (CATSI-EDM

Il y a un résumé en français ici.

Report Number
DRDC-VALCARTIER-TR-2006-634 — Technical Report
Date of publication
01 Apr 2007
Number of Pages
84
DSTKIM No
CA029237
CANDIS No
527481
Format(s):
CD ROM

Permanent link

Document 1 of 1

Date modified: