Measured and modeled long-wave infrared signature of Quest in Q280

PDF

Authors
  1. Zahir, A.
  2. Hutt, D.L.
  3. Moura, V.
Corporate Authors
Defence R&D Canada - Atlantic, Dartmouth NS (CAN)
Abstract
Canadian Forces Auxiliary Vessel (CFAV) Quest was imaged in the long-wave infrared (IR) band during DRDC Atlantic sea trial Q280 in February 2004. From images collected over several days, we have extracted the ship, sea and sky radiances. A contrast radiance between the ship and the background was calculated to determine the long-wave IR signature. Our analysis shows that the daytime signature of the vessel is larger than at night in the long-wave IR band. The contrast radiance of the stack exceeds that from the hull when contrasted against the winter sea. And finally, by comparing with prior studies, we note that the contrast ratio is larger in the mid-wave IR than in the long-wave IR when the contrast is constrained to the ship stack. We used ShipIR to model the Quest and its maritime environment. We found that the results were in general agreement with the measured data for both the sea and sky background and the ship surface. Overall, the typical difference between measured and modeled results was about 10 - 30%.

Il y a un résumé en français ici.

Report Number
DRDC-ATLANTIC-TM-2007-309 — Technical Memorandum
Date of publication
01 Mar 2008
Number of Pages
40
DSTKIM No
CA033106
CANDIS No
532399
Format(s):
Electronic Document(PDF)

Permanent link

Document 1 of 1

Date modified: