VOLTAGE NOISE MEASUREMENTS ON SEALED LEAD ACID BATTERIES

PDF

Authors
  1. Roberge, P.R.
  2. Verville, G.
  3. Beaudoin, R.
  4. Smit, J.
Corporate Authors
Royal Military Coll of Canada, Kingston ONT (CAN) Dept of Chemistry and Chemical Engineering;Ottawa Univ, Ottawa ONT (CAN) Electrochemical Science and Technology Centre;Chief of Research and Development, Ottawa ONT (CAN) Director Research and Development Air
Abstract
Voltage fluctuations observed during normal operation of sealed lead acid cells have given rise to an investigation on the potential of electrical noise monitoring as a characterization technique for specific problems associated with such sealed systems. The use of a cadmium reference electrode inserted in the mandrel of the Gates "J" type cells permitted to correlate different noise patterns with critical conditions of operation and assign them to either the positive or negative electrode.
Date of publication
01 Jan 1989
Number of Pages
25
DSTKIM No
91-03735
CANDIS No
70925
Format(s):
Document Image stored on Optical Disk;Originator's fiche received by DSIS