EXTERNAL WORK OF BREATHING OF DEMAND-AIR UNDERWATER BREATHING APPARATUS

Authors
  1. Grodski, J.J.
Corporate Authors
Defence and Civil Inst of Environmental Medicine, Downsview ONT (CAN)
Abstract
Underwater breathing apparatus can be effectively evaluated by measuring the external work of breathing. The paper reviews the existing and the proposed standards for demand-air breathing apparatus and recommends improvements to the Bentley-Reimers criterion. An automated method of collecting data on the external work of breathing is also described along with test results of various demand-air breathing apparatus. The test and evaluation data in the paper support the proposed, modified Bentley-Reimers criterion.